bison logo

How does ATS work with generators

In this article, BISON will explore how an ATS enhances generator performance and ensures seamless power transfer.

Table of Contents

How automatic transfer switches ensuring generator uninterrupted power!

Continuous power is crucial today, and generators are key in delivering dependable backup power during outages. They keep homes, businesses, and essential facilities running smoothly when the grid goes down. But for a generator to be fully effective, it needs more than just to be on standby. It requires seamless integration. This is where an automatic transfer switch (ATS) becomes important. An ATS detects power outages and enables a quick, smooth switch to backup power.

In this article, BISON will explore how an ATS enhances generator performance and ensures seamless power transfer. Discover the features and types of ATS and its operation with generators. Whether you’re managing a home or a facility, understanding this synergy helps you for keeping working.

Understanding ATS

Purpose of ATS

The main function of an ATS is to automatically switch the electrical load from the utility to a generator during a fault, and switch back when utility power returns. This automated process avoids interruptions and safeguards sensitive equipment from outages.

Key Components of an ATS

Switches

The switches in an ATS transfer loads between power sources. They connect only one power source at a time to the load, preventing backfeed and maintaining safe operation.

Control Circuits

Control circuits are the brains of the ATS. They monitor the power status and control the switching process. These circuits detect voltage drops or faults and initiate the transfer process. Once normal power is restored, they manage the transfer back to utility power.

Types of ATS

Open Transfer

Open transfer switches briefly disconnect power when switching between power sources. While this causes a brief interruption, it is sufficient for most applications where a momentary power outage can be acceptable.

Enclosed Transfer

Enclosed transfer switches ensure seamless transfers without interrupting power. They temporarily connect the two power sources to ensure continuity, making them ideal for critical systems where even a brief power outage is unacceptable.

Static Transfer Switches

Static transfer switches use electronic components rather than mechanical components to transfer loads. This allows for extremely fast switching, suitable for applications where power needs to be transferred instantly without any delays.

These ATS types offer flexibility, allowing users to select the most appropriate option for their specific power reliability needs. Understanding these differences is critical when designing a backup power solution for unique operational requirements.

How an ATS Works with Generators

Power Failure Detection

The ATS continuously monitors the incoming utility power for abnormal conditions such as voltage drops or complete power outages. It uses specially designed sensors to detect these interruptions in a timely manner. When the ATS detects a power failure, it verifies that the utility power is indeed lost and a switchover is required. It immediately begins the transfer process.

Generator Activation

The ATS sends a start signal to the generator to initiate its operation.

It is also worth noting that a time delay is programmed into the ATS to prevent unnecessary generator starts during brief power failures. This delay also allows the generator to warm up and stabilize, ensuring optimal performance.

Load Transfer

Once the generator reaches appropriate operating parameters, ATS transfers the load from the utility power to generator. This requires disconnecting the utility power and connecting generator to the load. Before the actual load transfer, ATS ensures that voltage and frequency of generator are synchronized with the requirements of the load to maintain stability and prevent damage.

Monitoring Power Quality

During generator operation, the ATS continuously checks voltage, frequency and current parameters to ensure they are within acceptable ranges for safe operation. If any anomalies or faults are detected, ATS initiates an automatic shutdown to protect generator and connected equipment.

Switching Back to Primary Power

The ATS monitors the restoration of utility power. It detects when primary power is stable and within preset thresholds and switches back to primary power.

To ensure a safe return to utility power, the ATS checks that voltage, frequency, and any power conditions are stable before switching the load.

Reconnection Process

After confirming that utility power is stable, the ATS switches the load back to utility power and disconnects generator. Waiting for generator to cool down allows generator to run without load, dissipate excess heat, and ensure long life and ready availability. Once cooled down, the generator receives a signal to shut off.

ATS-works-with-generator

Benefits of using ATS with a Generator

Seamless Power Transfer

The ATS smoothly switches from utility to generator power, avoiding disruptions. This smooth transition is crucial for continuous operation of critical areas like hospitals and data centers.

Protecting Sensitive Machinery

An ATS synchronizes voltage and frequency, shielding sensitive electronics from power surges. This prevents damage and guarantees top performance.

Reduce Downtime

Through automatic detection and activation, an ATS can significantly reduce downtime during power outages, allowing businesses and homes to continue operating with less disruption.

Key Considerations for Installation

Choosing the Right ATS for Your Generator

  • Compatibility: Make sure the ATS matches the capacity and specifications of your generator.
  • Features: Consider ATS models with features tailored to your specific needs, such as remote monitoring or advanced diagnostics.

The Importance of Professional Installation

  • Expertise: Professional installers ensure the ATS integrates properly with your generator system and adheres to all safety codes and standards.
  • Safety: Proper installation reduces the risk of failure and potential hazards.

Regular Maintenance and Testing

  • Routine Inspections: Regular inspections and testing ensure ATS and generator are operating properly and are ready for use.
  • Performance Verification: Maintenance helps detect potential problems early, ensuring reliability during power outages.

Conclusion

This article explores how and what benefits an automatic transfer switch (ATS) can provide to enhance generator functionality. It also highlights key considerations when installing an ATS and pairing it effectively with your generator for optimal reliability. Professional installation and a routine maintenance program are essential to maintain functionality and safety. By taking these steps, you can ensure a reliable backup power system that can meet your needs when the primary power fails. Investing in a robust ATS and generator setup is a proactive step toward uninterruptible power security.

Get in touch to speak with our experts!

Related articles

can run a diesel generator on kerosene

can you run a diesel generator on kerosene?

Using kerosene in diesel generator is possible but not recommended for long-term use due to potential damage from lower lubricity and hotter burning properties.
diesel generators vs petrol generators

Diesel generators vs petrol generators

Learn about the differences in performance, efficiency & suitability of diesel and petrol generators for various applications. Read this blog post to find out.

how to drain gasoline from your generator

Since old gasoline can cause starting problems, knowing how to safely drain generator gasoline is an important part of keeping your generator in top condition.
can-you-use-red-diesel-in-a-generators

can you use red diesel in a generator?

BISON will analyze in depth the key issues of fuel selection for diesel generators, clarifying ideas and considering the environmental impact of red diesel.

Related products

remote start three phase gasoline generator-2

remote start three phase gasoline generator

BISON BS7500SM is a professional grade gasoline generator ideal for a variety of applications including construction, manufacturing, and events.
china-ohv-7hp-petrol-power-generator-3

china ohv 7hp petrol power generator

Chinese professional grade gasoline generator, ideal for a variety of applications. Equipped with a 7HP OHV engine, which can provide a maximum power of 3.0KW.
6500w-air-cold-petrol-generator-15hp

6500w air cold petrol generator 15hp

The BS3500SC 15hp recoil start petrol generator is ruggedly constructed for frequent use in a variety of environments, making it a wise investment.
2-cylinder-10kw-silent-diesel-generator-home-use

2-cylinder 10kw silent diesel generator home use

BS12000DSE, produced in China by BISON diesel generator manufacturer, is a premium 10kW silent diesel generator designed specifically for home use.

enquire today

Speak with our sales manager today for additional information or an obligation-free quote.