16kw two-cylinder three-phase electric generator
within 25 days delivery time after receiving the deposit!
The BS22000 is an industrial-grade 16kw generator that delivers exceptional performance and ease of use for construction sites, industrial facilities and more.
Main features and advantages of 16kw two-cylinder three-phase generator:
- Powerful 16 kw output: Provides enough power to operate multiple devices and power tools simultaneously.
- Twin-cylinder engine: smooth operation and long service life.
- electric start: Start your engine quickly and easily even in cold conditions.
- Three-phase output: Ideal for powering three-phase motors commonly used in industry.
- Wheels: Portable so the generator can be easily moved to different job sites.
features
convenient electric start
BISON is a reputable petrol generator manufacturer dedicated to providing quality and reliable petrol generators. The BS22000 is able to withstand harsh application environments to ensure longevity and performance.
BISON two-cylinders electric generator has a solid structure. Engineered to extend service life and reduce downtime and maintenance costs.
From overload protection to low oil shutdown, the BS22000 prioritizes your operating conditions.
Two-cylinder powerhouse
The BS22000 three-phase electric generator is equipped with a powerful two-cylinder engine which enhances its durability and performance. Ensure smooth and efficient power transmission.
With its advanced design, the BISON 16kw three-phase generator ensures optimal performance, delivering consistent, reliable power to critical applications.
Remotely access key data and performance indicators and take control from anywhere with the BS22000’s remote monitoring capabilities.
specifications
output | |
---|---|
rated power | 15.0 KW |
maximum power | 16.5 KW |
Phase | single-phase / three-phases (optional) |
AC voltage | depends on your country’s voltage |
single-phase AC amperage | running power ÷ using voltage |
three-phase AC amperage | running power ÷ using voltage ÷ 1.3856 |
frequency | 50 / 60 HZ |
continuous operating time | 4.5 h |
engine & emission | |
---|---|
engine type | 4-stroke, OHV, air-cooled |
engine model name | R999 |
bore × stroke | 2-90 × 78.5 MM (Two-Cylinders) |
engine displacement | 999 CC |
engine speed | 3000(50 Hz) / 3600(60 Hz) RPM |
recoil start | / |
electric start | yes |
alternator | |
---|---|
winding material | 100% copper winding |
power factor | 1.0 (single-phase) / 0.8 (three-phase) |
fuel system | |
---|---|
fuel tank capacity | 35 l |
oil capacity | 2.8 l |
packaging | |
---|---|
carton dimensions (no wheels & handles) | 1020 × 680 × 910 MM |
generator net weight | 200 KGS |
carton gross weight | 212 KGS |
optional
The open frame type gasoline generators above 5 kilowatts should choose this option.
wheels & handles
easy to move the generator
The open frame type gasoline generators above 5 kilowatts should choose this option.
electric & remote start
easy to start the generator
The customers who have high-end pursue of generator should choose this option.
digital display
easy to monitor the generator
The generators above 7 kilowatts or have three-phase voltage should choose this option.
industrial socket
power for industrial use
When you take generators as backup power, you could choose this. ATS is not necessary for small kilowatts.
ATS
automatically start without human intervention required
factory
overview
how we test the gasoline generator
Ensure the engine better store energy and inertia.
flywheel clearance
Ensure the alternator could output current stably.
power debugging
Ensure the stability and sealing of the fuel tank.
fuel tank airtight
Ensure the sealing of alternator is stable.
alternator air gap
Ensure the sealing of cylinder head is intact.
cylinder head seal
Ensure a stable connection between the connecting rod and crankshaft.
connecting rod torque
Ensure the cylinder head connection is stable.
cylinder head torque
Ensure the crankcase torque is correct and the same for each engine.
crankcase torque
Ensure the sealing of the engine is stable.
air tightness test
Ensure the muffler connection is stable.
muffler tightening torque
Ensure stable performance and output of the generator.
comprehensive performance test
Ensure the voltage of generator is stable.
voltage test
Ensure the generator has no cosmetic defects.
appearance final inspection
Ensure we don’t miss any accessories in the carton.
weighing check
Well-packaged and ensure the safety of the generator.
packaging
support
agent service
※How to become a BISON agent: achieve orders of more than USD 1 million of BISON brand products in one year.
※What can you get after becoming an agent:
We will assist you in building a BISON supermarket store locally
Give you free display racks and display cabinets
Provide you with free decoration design services.
……
※At the same time, enjoy the supreme VIP warranty experience and service!
customs services
※ We can find the cheapest sea shipping price for you.
※ We can find a local customs clearance agent for you.
※ In some special cases, we can save you import tariff costs.